Brands / Senninger

Xi-Wob

About this family

The Xi-Wob™ takes the instantaneous, uniform distribution pattern popularized by the i-Wob®2 to semi-rigid PE and steel drops. It provides the same low operating pressure, wide area of coverage, and low application intensity that has made the i-Wob2 the leading pivot sprinkler on the market.

Three deflector models based on desired trajectory and droplet size.

Features

  • Low vibration makes it ideal for semi-rigid PE and steel drops
  • Low operating pressures of 10 to 15 psi (0.69 to 1.03 bar) save energy and money

Xi-Wob Design Criteria

Model 610 (Blue) 6-Groove 10º Trajectory Medium DropletsModel 615 (Black) 6-Groove 15º Trajectory Large DropletsModel 910 (Grey) 9-Groove 10º Trajectory Small Droplets
Nozzle sizes: Minimum#7 7/64" (2.78 mm)#10 5/32" (3.97 mm)#10 5/32" (3.97 mm)
Nozzle sizes: Maximum*#24 3/8" (9.53 mm)#24 3/8" (9.53 mm)#24 3/8" (9.53 mm)
Flows: Minimum1.09 gpm (248 L/hr)2.24 gpm (509 L/hr)2.24 gpm (509 L/hr)
Flows: Maximum15.78 gpm (3584 L/hr)15.78 gpm (3584 L/hr)15.78 gpm (3584 L/hr)
Diameters: Minimum at 3 ft (0.91 m)30 ft (9.1 m)38 ft (11.6 m)33 ft (10.1 m)
Diameters: Maximum at 3 ft (0.91 m)41 ft (12.5 m)43 ft (13.1 m)36 ft (11.0 m)
Diameters: Minimum at 6 ft (1.83 m)35 ft (10.7 m)43 ft (13.1 m)38 ft (11.6 m)
Diameters: Maximum at 6 ft (1.83 m)45 ft (13.7 m)50 ft (15.2 m)43 ft (13.1 m)
Diameters: Minimum at 9 ft (2.74 m)37 ft (11.3 m)46 ft (14.0 m)43 ft (13.1 m)
Diameters: Maximum at 9 ft (2.74 m)47 ft (14.3 m)55 ft (16.8 m)50 ft (15.2 m)
Maximum Spacing** at 6 ft (1.8 m) ground clearance18 ft (5.5 m)20 ft (6.1 m)18 ft (5.5 m)
Maximum Spacing** at 9 ft (2.74 m) ground clearance18 ft (5.5 m)20 ft (6.1 m)18 ft (5.5 m)
Maximum Spacing** at 12 ft (3.66 m) ground clearance---------
Pressure at the Nozzle: Minimum10 psi (0.69 bar)10 psi (0.69 bar)10 psi (0.69 bar)
Pressure at the Nozzle: Maximum15 psi (1.03 bar)15 psi (1.03 bar)15 psi (1.03 bar)

*It is recommended that larger nozzle sizes be used only on soils that can handle higher application rates.

** For optimum performance, Senninger recommends the use of maximum spacing for 1-2 spans only.

Note: When outlet spacing exceeds 10 ft (3.0 m), keep the Xi-Wob above crop canopy. This is especially important on high profile crops.

Not warrantied for rigid installation on offsets or booms larger than 10.5 ft (3.2 m). Longer offsets and booms require a minimum of 2 ft (0.61 m) reinforced flex hose.

Gallery

  • Senninger Xi-Wob sprinkler

Models

Model numberDescriptionBox qtyBox wt
XIWOB00B3610UP36 grooves, 10-degree trajectory (blue deflector), 3/4" M NPT (excluding nozzle)8037 lb
XIWOB00B3615UP36 grooves, 15-degree trajectory (black deflector), 3/4" M NPT (excluding nozzle)8037 lb
XIWOB00B3910UP39 grooves, 10-degree trajectory (grey deflector), 3/4" M NPT (excluding nozzle)8037 lb